Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment

Product Details
Material: Cold-Rolled Steel Coated with Powders
Type: Vav or VAC
Function: Exhaust, Velocity Control
Manufacturer/Factory, Trading Company
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
101~500 square meters
  • Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
  • Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
  • Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
  • Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
  • Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
  • Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
Find Similar Products

Basic Info.

Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
White
Customized
Customized
Condition
New
Other Type
Walk-in Fume Hood
Worktop
Phenolic Resin, Epoxy Resin, Ceramic etc
Other Material
PP, FRP, Stainless Steel etc
Transport Package
Bubble Film+Hard Cotton+Wooden Package
Specification
1200/1500/1800*850*2600mm
Origin
China
HS Code
8414809090
Production Capacity
1000 Sets / Year

Product Description

ASHRAE110-2016 US Standard Lab Fume Hood Lab Equipment. 

Fume Hood Introduction 

Service 
Selection of the proper type of fume hood to use in a lab should be based on the actual requirements. Penway Science fume hood is made of ceramic fiber aluminum, steel.

Safety
Plays as a pioneer in lab industry
Fume hood VAV valve
Air differential pressure control system for air output and compensation
Third-party on-site inspection
Those four points can make the laboratory to be safe

Health
European and US design, integrated frames.
The sash slideway, balance weight, communication system all of those are embedded in fume hood`s front aluminum frames.

Category
Modular frames design.
The front frame is made of aluminum environmental protection material.
The back frame is made of high-quality steel plate - Baosteel


Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment


Constant air volume principle (CAV)
Conventional hood: This term is used to describe a constant air volume (CAV) hood, an older, traditinally less elaborate hood design used for general protection of the laboratory worker. Because the amount elaborate hood design used for general protection of the laboratory worker. Because the amount of exhausted air is constant, the face velocity of a CAV hood is inversely proportional to the sash height. That is, the lower the sash, the higher the face velocity. CAV hoods can be installed with or without a bypass provision which is an additional opening for air supply into the hood.

Variable air volume vs. constant air volume?
• Constant volume is good for small applications, for dedicated exhaust, or for two to four units sharing an exhaust.
• Most hoods have "setup" time and "run" time, or are only used on a limited basis. While slightly more expensive to buy, that makes a two-speed exhaust more cost effective in use. Typically, low speed is 50% of high speed. Set the blower on high for setup, low for runtime, or for limited-use purposes.
• Hoods should be in close proximity to one another to save money on installing and maintaining the exhaust system.
• You can also plan for future hoods to be added to the system. But make sure future expansion is identified in the building plan, so that the whole building exhaust and supply can accommodate future needs. For example, you can buy a blower for a 4-hood system when you're only planning to install two hoods at first. Then just block off your "future" duct until you buy the additional hoods.


Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment


 

Fume Hood Comparison Table
  Standard NO. Leakage Rage / ppm Air Velocity / m/s Requirements Air Exhaust / m3/h at 500m Energy Comsumption
Domestic Standard JB-T 6412-1999 0.5 0.5 Basic Need 1250 100%
US Standard ASHRAE 110-2016 0.05 0.5 Basic Need 1250 100%
European Standard EN 14175 0.01 0.3-0.5 Sash Open to 500mm Height 600 52%


 

Model Bench-top  Low-worktop Bench-top Walk-in
Height  2400mm 2600mm Customized
Width 1200mm 1500mm 1800mm
Glass LGGlass (Laminated Glass)
Inner Liner HPL (Phenolic Compact Laminate) Phenolic Resin  Ceramic
Worktop Phenolic Resin  Epoxy Resin  Ceramic
Receptacle 4 pcs 6 pcs Others
Water Supply 1 pcs 2 pcs Others
Gas Supply 1 pcs 2 pcs Others
Base Cabinet Single Door Cabinet  Double Door Cabinet  Others 

Ashrae110-2016 Us Standard Lab Fume Hood Lab Equipment
 