  • European Standard Compliance: Meets EN 14175 standard with 0.01 ppm leakage rate and 0.3-0.5 m/s air velocity.
  • Customizable Dimensions: Available in standard and customized widths including 1200mm, 1500mm, and 1800mm.
  • Diverse Material Options: Worktops and materials include Phenolic Resin, Epoxy Resin, Ceramic, PP, FRP, and Stainless Steel.
  • Advanced Safety Features: Features corrosion, heat, acid, alkali resistance, fireproof, and explosion-proof capabilities.
  • Energy Efficient Design: European standard consumes only 52% energy compared to domestic and US standards.
  • Integrated Aluminum Frame: Front frame made of environmental aluminum with embedded sash slideway and balance weight.
  • Flexible Air Volume Control: Supports both Constant Air Volume (CAV) and Variable Air Volume (VAV) systems.
  • Fast Production Lead Time: Peak and off-peak season lead time is within 15 working days.

Product Images of En14175 European Standard Fume Hood Lab Equipment

En14175 European Standard Fume Hood Lab Equipment
En14175 European Standard Fume Hood Lab Equipment pictures & photos
En14175 European Standard Fume Hood Lab Equipment
En14175 European Standard Fume Hood Lab Equipment pictures & photos
En14175 European Standard Fume Hood Lab Equipment
En14175 European Standard Fume Hood Lab Equipment pictures & photos
En14175 European Standard Fume Hood Lab Equipment
En14175 European Standard Fume Hood Lab Equipment pictures & photos
En14175 European Standard Fume Hood Lab Equipment
En14175 European Standard Fume Hood Lab Equipment pictures & photos
En14175 European Standard Fume Hood Lab Equipment
En14175 European Standard Fume Hood Lab Equipment pictures & photos
En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
    En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
    En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
    En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
    En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
    En14175 European Standard Fume Hood Lab Equipment
  • En14175 European Standard Fume Hood Lab Equipment
    En14175 European Standard Fume Hood Lab Equipment

Find Similar Products

Product Description

Manufacturer of EN14175 European Standard Fume Hood Lab Equipment from China manufacturer. 

Fume Hood Introduction 

Service 
Selection of the proper type of fume hood to use in a lab should be based on the actual requirements. Penway Science fume hood is made of ceramic fiber aluminum, steel.

Safety
Plays as a pioneer in lab industry
Fume hood VAV valve
Air differential pressure control system for air output and compensation
Third-party on-site inspection
Those four points can make the laboratory to be safe

Health
European and US design, integrated frames.
The sash slideway, balance weight, communication system all of those are embedded in fume hood`s front aluminum frames.

Category
Modular frames design.
The front frame is made of aluminum environmental protection material.
The back frame is made of high-quality steel plate - Baosteel


En14175 European Standard Fume Hood Lab Equipment


Constant air volume principle (CAV)
Conventional hood: This term is used to describe a constant air volume (CAV) hood, an older, traditinally less elaborate hood design used for general protection of the laboratory worker. Because the amount elaborate hood design used for general protection of the laboratory worker. Because the amount of exhausted air is constant, the face velocity of a CAV hood is inversely proportional to the sash height. That is, the lower the sash, the higher the face velocity. CAV hoods can be installed with or without a bypass provision which is an additional opening for air supply into the hood.

Variable air volume vs. constant air volume?
• Constant volume is good for small applications, for dedicated exhaust, or for two to four units sharing an exhaust.
• Most hoods have "setup" time and "run" time, or are only used on a limited basis. While slightly more expensive to buy, that makes a two-speed exhaust more cost effective in use. Typically, low speed is 50% of high speed. Set the blower on high for setup, low for runtime, or for limited-use purposes.
• Hoods should be in close proximity to one another to save money on installing and maintaining the exhaust system.
• You can also plan for future hoods to be added to the system. But make sure future expansion is identified in the building plan, so that the whole building exhaust and supply can accommodate future needs. For example, you can buy a blower for a 4-hood system when you're only planning to install two hoods at first. Then just block off your "future" duct until you buy the additional hoods.


En14175 European Standard Fume Hood Lab Equipment


 

Fume Hood Comparison Table
  Standard NO. Leakage Rage / ppm Air Velocity / m/s Requirements Air Exhaust / m3/h at 500m Energy Comsumption
Domestic Standard JB-T 6412-1999 0.5 0.5 Basic Need 1250 100%
US Standard ASHRAE 110-2016 0.05 0.5 Basic Need 1250 100%
European Standard EN 14175 0.01 0.3-0.5 Sash Open to 500mm Height 600 52%


 

Model Bench-top  Low-worktop Bench-top Walk-in
Height  2400mm 2600mm Customized
Width 1200mm 1500mm 1800mm
Glass LGGlass (Laminated Glass)
Inner Liner HPL (Phenolic Compact Laminate) Phenolic Resin  Ceramic
Worktop Phenolic Resin  Epoxy Resin  Ceramic
Receptacle 4 pcs 6 pcs Others
Water Supply 1 pcs 2 pcs Others
Gas Supply 1 pcs 2 pcs Others
Base Cabinet Single Door Cabinet  Double Door Cabinet  Others 

En14175 European Standard Fume Hood Lab Equipment
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR251792". Items marked "verified" are certified.

Watch Video
Watch Video
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 205 Building 4th No.95 Daguan Middle Road Tianhe District Guangzhou China
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Guangzhou Huang Pu Port, Nansha Port, Shenzhen Yantian Port

Our Production Capability & Technical Expertise

Main Products
Lab Furniture, Lab Bench, Lab Table, Fume Hood, Fume Cupboard, Lab Construction, Lab Designs, Lab Cabinets, Lab Equipment

Our Industry Experience & Global Business Record

Export Year
2018-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What standards does the fume hood meet?
It meets the EN 14175 European Standard with a leakage rate of 0.01 ppm and air velocity of 0.3-0.5 m/s.
Can the fume hood dimensions be customized?
Yes, widths are available in 1200mm, 1500mm, and 1800mm, and heights can be customized up to 2600mm.
What materials are used for the worktop?
Worktops are available in Phenolic Resin, Epoxy Resin, and Ceramic options.
Is the fume hood explosion-proof?
Yes, the hood features fireproof, explosion-proof, and acid & alkali resistant properties.
How long is the production lead time?
The lead time is within 15 working days for both peak and off-peak seasons.
What payment terms are accepted?
We accept LC, T/T, and Western Union as payment terms.
What is the energy consumption compared to other standards?
The European standard consumes 52% energy, while domestic and US standards consume 100%.