En Standard High Performance Vav Fume Hood Fan Fume Cupboard

  • Audited Supplier
  • 9 yrs

Contact Supplier

Product Highlights

  • Customized Dimensions: Available in widths of 1200mm, 1500mm, and 1800mm to fit specific lab layouts.
  • Variable Air Volume Control: VAV system ensures constant face velocity and energy efficiency compared to CAV hoods.
  • High Safety Standards: Meets EN 14175, ASHRAE 110-2016, and JB-T 6412-1999 with leakage rates as low as 0.01 ppm.
  • Durable Material Options: Constructed with painted steel, aluminum frames, and worktops like Phenolic Resin or Ceramic.
  • Corrosion and Heat Resistance: Designed to withstand acid, alkali, fire, and explosion risks in chemical experiments.
  • Modular Frame Design: Integrated aluminum front frames and steel back frames allow for easy expansion and maintenance.
  • Energy Efficient Operation: European standard design reduces energy consumption to 52% compared to domestic standards.
  • Fast Lead Time: Peak and off-peak season delivery completed within 15 working days.

Product Images of En Standard High Performance Vav Fume Hood Fan Fume Cupboard

En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard pictures & photos
En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard pictures & photos
En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard pictures & photos
En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard pictures & photos
En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard pictures & photos
En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard pictures & photos
En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
    En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
    En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
    En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
    En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
    En Standard High Performance Vav Fume Hood Fan Fume Cupboard
  • En Standard High Performance Vav Fume Hood Fan Fume Cupboard
    En Standard High Performance Vav Fume Hood Fan Fume Cupboard

Find Similar Products

Product Description

EN Standard High Performance VAV Fume Hood Fan Fume Cupboard


Fume Hood Introduction 

Service 
Selection of the proper type of fume hood to use in a lab should be based on the actual requirements. Penway Science fume hood is made of ceramic fiber aluminum, steel.

Safety
Plays as a pioneer in lab industry
Fume hood VAV valve
Air differential pressure control system for air output and compensation
Third-party on-site inspection
Those four points can make the laboratory to be safe

Health
European and US design, integrated frames.
The sash slideway, balance weight, communication system all of those are embedded in fume hood`s front aluminum frames.

Category
Modular frames design.
The front frame is made of aluminum environmental protection material.
The back frame is made of high-quality steel plate - Baosteel


En Standard High Performance Vav Fume Hood Fan Fume Cupboard


Constant air volume principle (CAV)
Conventional hood: This term is used to describe a constant air volume (CAV) hood, an older, traditinally less elaborate hood design used for general protection of the laboratory worker. Because the amount elaborate hood design used for general protection of the laboratory worker. Because the amount of exhausted air is constant, the face velocity of a CAV hood is inversely proportional to the sash height. That is, the lower the sash, the higher the face velocity. CAV hoods can be installed with or without a bypass provision which is an additional opening for air supply into the hood.

Variable air volume vs. constant air volume?
• Constant volume is good for small applications, for dedicated exhaust, or for two to four units sharing an exhaust.
• Most hoods have "setup" time and "run" time, or are only used on a limited basis. While slightly more expensive to buy, that makes a two-speed exhaust more cost effective in use. Typically, low speed is 50% of high speed. Set the blower on high for setup, low for runtime, or for limited-use purposes.
• Hoods should be in close proximity to one another to save money on installing and maintaining the exhaust system.
• You can also plan for future hoods to be added to the system. But make sure future expansion is identified in the building plan, so that the whole building exhaust and supply can accommodate future needs. For example, you can buy a blower for a 4-hood system when you're only planning to install two hoods at first. Then just block off your "future" duct until you buy the additional hoods.


En Standard High Performance Vav Fume Hood Fan Fume Cupboard




 

Fume Hood Comparison Table
  Standard NO. Leakage Rage / ppm Air Velocity / m/s Requirements Air Exhaust / m3/h at 500m Energy Comsumption
Domestic Standard JB-T 6412-1999 0.5 0.5 Basic Need 1250 100%
US Standard ASHRAE 110-2016 0.05 0.5 Basic Need 1250 100%
European Standard EN 14175 0.01 0.3-0.5 Sash Open to 500mm Height 600 52%


 

Model Bench-top  Low-worktop Bench-top Walk-in
Height  2400mm 2600mm Customized
Width 1200mm 1500mm 1800mm
Glass LGGlass (Laminated Glass)
Inner Liner HPL (Phenolic Compact Laminate) Phenolic Resin  Ceramic
Worktop Phenolic Resin  Epoxy Resin  Ceramic
Receptacle 4 pcs 6 pcs Others
Water Supply 1 pcs 2 pcs Others
Gas Supply 1 pcs 2 pcs Others
Base Cabinet Single Door Cabinet  Double Door Cabinet  Others 

En Standard High Performance Vav Fume Hood Fan Fume Cupboard
En Standard High Performance Vav Fume Hood Fan Fume Cupboard

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR251792". Items marked "verified" are certified.

Watch Video
Watch Video
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 205 Building 4th No.95 Daguan Middle Road Tianhe District Guangzhou China
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Guangzhou Huang Pu Port, Nansha Port, Shenzhen Yantian Port

Our Production Capability & Technical Expertise

Main Products
Lab Furniture, Lab Bench, Lab Table, Fume Hood, Fume Cupboard, Lab Construction, Lab Designs, Lab Cabinets, Lab Equipment

Our Industry Experience & Global Business Record

Export Year
2018-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What standards does this fume hood meet?
It meets EN 14175 (European), ASHRAE 110-2016 (US), and JB-T 6412-1999 (Domestic) standards.
Is the size customizable?
Yes, widths are available in 1200mm, 1500mm, and 1800mm, and heights up to 2600mm.
What materials are used for the worktop?
Options include Phenolic Resin, Epoxy Resin, and Ceramic.
How does the VAV system work?
It maintains constant face velocity regardless of sash height, unlike Constant Air Volume (CAV) hoods.
What is the delivery time?
Both peak and off-peak season lead times are within 15 working days.
What payment terms are accepted?
We accept LC, T/T, and Western Union.
Is the product new?
Yes, the condition is listed as New.
What are the main features of the hood?
It features corrosion resistance, heat resistance, acid & alkali resistance, fireproofing, and explosion proofing.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now