En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood

  • Audited Supplier
  • 9 yrs

Contact Supplier

Product Highlights

  • Dual Standard Compliance: Meets EN14175 European and ASHRAE110-2016 US standards for safety.
  • Customizable Design: Offers customized types, materials, and sizes for various lab needs.
  • Advanced VAV Control: Features VAV valve and air differential pressure control for safety.
  • High Durability: Resistant to corrosion, heat, acid, alkali, fire, and explosion.
  • Energy Efficient: European standard design reduces energy consumption to 52%.
  • Modular Frame System: Integrated aluminum and steel frames with embedded components.
  • Multiple Material Options: Worktops available in Phenolic, Epoxy, Ceramic, and other materials.
  • Fast Delivery: Average lead time within 15 workdays for both peak and off seasons.

Product Images of En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood

En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood pictures & photos
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood pictures & photos
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood pictures & photos
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood pictures & photos
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood pictures & photos
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood pictures & photos
En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
    En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
    En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
    En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
    En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
    En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
  • En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
    En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood

Find Similar Products

Product Description

EN14175 Eropean Standard And ASHRAE110-2016 US Standard Lab Fume Cupboard Fume Hood

Fume Hood Introduction 

Service 
Selection of the proper type of fume hood to use in a lab should be based on the actual requirements. Penway Science fume hood is made of ceramic fiber aluminum, steel.

Safety
Plays as a pioneer in lab industry
Fume hood VAV valve
Air differential pressure control system for air output and compensation
Third-party on-site inspection
Those four points can make the laboratory to be safe

Health
European and US design, integrated frames.
The sash slideway, balance weight, communication system all of those are embedded in fume hood`s front aluminum frames.

Category
Modular frames design.
The front frame is made of aluminum environmental protection material.
The back frame is made of high-quality steel plate - Baosteel


En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood


Constant air volume principle (CAV)
Conventional hood: This term is used to describe a constant air volume (CAV) hood, an older, traditinally less elaborate hood design used for general protection of the laboratory worker. Because the amount elaborate hood design used for general protection of the laboratory worker. Because the amount of exhausted air is constant, the face velocity of a CAV hood is inversely proportional to the sash height. That is, the lower the sash, the higher the face velocity. CAV hoods can be installed with or without a bypass provision which is an additional opening for air supply into the hood.

Variable air volume vs. constant air volume?
• Constant volume is good for small applications, for dedicated exhaust, or for two to four units sharing an exhaust.
• Most hoods have "setup" time and "run" time, or are only used on a limited basis. While slightly more expensive to buy, that makes a two-speed exhaust more cost effective in use. Typically, low speed is 50% of high speed. Set the blower on high for setup, low for runtime, or for limited-use purposes.
• Hoods should be in close proximity to one another to save money on installing and maintaining the exhaust system.
• You can also plan for future hoods to be added to the system. But make sure future expansion is identified in the building plan, so that the whole building exhaust and supply can accommodate future needs. For example, you can buy a blower for a 4-hood system when you're only planning to install two hoods at first. Then just block off your "future" duct until you buy the additional hoods.


En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood


 

Fume Hood Comparison Table
  Standard NO. Leakage Rage / ppm Air Velocity / m/s Requirements Air Exhaust / m3/h at 500m Energy Comsumption
Domestic Standard JB-T 6412-1999 0.5 0.5 Basic Need 1250 100%
US Standard ASHRAE 110-2016 0.05 0.5 Basic Need 1250 100%
European Standard EN 14175 0.01 0.3-0.5 Sash Open to 500mm Height 600 52%


 

Model Bench-top  Low-worktop Bench-top Walk-in
Height  2400mm 2600mm Customized
Width 1200mm 1500mm 1800mm
Glass LGGlass (Laminated Glass)
Inner Liner HPL (Phenolic Compact Laminate) Phenolic Resin  Ceramic
Worktop Phenolic Resin  Epoxy Resin  Ceramic
Receptacle 4 pcs 6 pcs Others
Water Supply 1 pcs 2 pcs Others
Gas Supply 1 pcs 2 pcs Others
Base Cabinet Single Door Cabinet  Double Door Cabinet  Others 

En14175 European Standard and Ashrae110-2016 Us Standard Lab Fume Cupboard Lab Fume Hood
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR251792". Items marked "verified" are certified.

Watch Video
Watch Video
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.
Guangzhou Penway Lab Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 205 Building 4th No.95 Daguan Middle Road Tianhe District Guangzhou China
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Guangzhou Huang Pu Port, Nansha Port, Shenzhen Yantian Port

Our Production Capability & Technical Expertise

Main Products
Lab Furniture, Lab Bench, Lab Table, Fume Hood, Fume Cupboard, Lab Construction, Lab Designs, Lab Cabinets, Lab Equipment

Our Industry Experience & Global Business Record

Export Year
2018-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What standards does this fume hood comply with?
It complies with EN14175 European Standard and ASHRAE110-2016 US Standard.
Is the fume hood customizable?
Yes, it supports customization for type, material, worktop, and usage scenarios.
What materials are used for the worktop?
Options include Phenolic Resin, Epoxy Resin, Ceramic, and others.
What is the average lead time for delivery?
The average lead time is within 15 workdays for both peak and off seasons.
What payment terms are accepted?
Accepted terms include LC, T/T, and Western Union.
What is the energy consumption compared to domestic standards?
European standard design reduces energy consumption to 52% compared to domestic standards.
What are the main markets for this product?
Main markets include North America, South America, Europe, Asia, Africa, and Oceania.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now