En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood

Product Specifications Select Now
EN FUME HOOD
1500*945*2400
1800*945*2400
Product Details
Customization: Available
Material: Cold-Rolled Steel
Type: Bypass Type
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Low MOQ
The MOQ for the supplier's products is 1
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (17)
  • En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
  • En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
  • En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
  • En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
  • En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
  • En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
Find Similar Products
  • Overview
  • Company Profile
  • Basic functions
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
PW-FM-15
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Optional
Customized
Customized
Condition
New
Worktop
Ceramic, Epoxy Resin etc
Interior
5mm Thickness of Compact Laminate Board
Glass
Transparent Tempered Glass
500mm Lock
Automatic Mechanical Lock
Design Standard
En14175 and Ashrae 110-2016
Transport Package
Wooden Package
Specification
1500*850*2350mm
Trademark
PENWAY
Origin
China
HS Code
9403
Production Capacity
1000 Sets / Year

Product Description

EN EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood
Company Profile

Guangzhou Penway Lab Equipment Co., Ltd is a company who is integrated lab overall design and planing, lab basic equipment manufacturing (lab furniture, fume hood.....) and sales and installation. Penway also supplies lab instruments with consumables; lab operation and maintenance. The pursuit of quality and excellent service is our mission. Penway Lab business scope covers laboratory designs and construction consulting, lab decorating engineering, lab HVAC engineering, lab furniture engineering, lab instruments with consumables; lab environmental protection engineering, lab gas supply engineering ect.

 
Basic functions

A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to:

*Protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes)
*Protect the product or experiment (biosafety cabinets, glove boxes)
*Protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream)


Selection of the proper type of fume hood to use in a laboratory should be based upon two interrelated considerations:
 
1:The hood must allow the user to perform the work in a safe, efficient manner.
2. The need to reduce air conditioning cost.

The interior of the Penway`s hood resists the corrosive effects of chemicals. The hood under structure should provide for storage of the required chemicals for the work being done in the hood. The total cost of a hood is greatly affected by its exhaust air requirements. The annual cost of heating and cooling the air exhausted by the hood can be as high as the initial cost of the hood itself. Choosing the proper hood type and sash configuration can significantly reduce these costs.

High Performance Fume Hoods:


En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood

Penway High-Performance/Low-Flow Fume Hoods
Compared to most traditional fume hoods, these high performance, low flow hoods are safer, have lower installation costs, and are up to 50% less expensive in operating costs. We have designed and installed fume hoods in labs around the world. 

Save Green with Environmentally-Conscious Fume Hood Models
High performance fume hoods has a series of design features to provide unsurpassed containment and operator protection:

1:Engineered baffle system provides proper air distribution
2:Constant air velocity (variable air volume) reduces energy use relative to sash position
3:Rounded corners at hood entrance reduce turbulence, improving efficiency
4:Aerodynamic sash pull
5:Containment trough with directional vanes and white Plascote finish adds durability and chemical resistance
6:Cord pass-through lets sash fully close without appliance cords getting in the way
7:Lower entrance safety bar provides a personal safety barrier 880mm high viewing area
8:White ResChem interior with vapor-proof fluorescent light.
9:458mm vertical opening with keyed sash stop to access 685mm set-up position
10:Double-wall construction for installation of plumbing and electrical service fixtures.


Advantages of High Performance Chemical Fume Hoods:

1:Engineered to exhaust 50% less conditioned air from the laboratory
2:Designed to capture fumes while working in modern laboratories with varying factors such as lab traffic, fluctuating temperatures.
3:Fume capture and containment can be demonstrated with tracer gas testing
5:Standard, available for all new chemical fume hood installations
6:Quiet operation
7:Low airflow provides an ideal environment for working with powders and delicate work.

Low-flow/high-performance hoods use substantially less energy to operate over the life-time of the fume hood exhaust system. Visit Laboratory Fume Hood Energy Model to calculate your energy needs. Penway has our own HVAC engineers to design the lab fume hood ventilation. From lab ventilation designs to construction, until system test and accept of work. Penway can provide one-stop service to customer.

 
Product Parameters
 
Type  EN or EU standard fume hood
Exhaust system CAV exhaust system (Constant air volume) / VAV exhaust system
Exhaust fan Inclined flow fan (The installation principle is the same as air conditioning) or Centrifugal fan
Exhaust air rate 1500-3500m3/h
Ventilation ducts (φ250 or 315mm)PVC material, FPR, PP or other
Power (Single-phase) 220V/50HZ or (Three-phase) 380V/50HZ
Air valve Manual or electric or VAV air valve
Average wind speed 0.3-0.6m/s adjustalbe
Noise level < 60dB(A)
Tops 12.7/16/19/mm thickness of Phenolic resin (Other: Epoxy resin, Ceramic etc)
Inner Liner Using HPL physiochemical board to make for lining plate and the flow guide plate

Cabinet

1.0mm thick cold-rolled steel with 75μm epoxy resin powder coating, most chemical resistant

Size

1200/1500/1800*945*2400 mm (customizable)

Visual windows

Transparent tempered glass

Opening height 20-700 mm

Control panel

Touch, intelligent control panel (can control lights, sockets, exhaust fan etc), display wind speed

Gross weight  280-400 kg
Motor power 0.5-1.1KW
Luminance >500LX
Lab accessories Pegboard, sink, faucet, gas fitting, sockets, lab stools etc
 
Detailed Photos

En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood

En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood

En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood

En EU Standard Energy-Saving Lab Steel Fume Cupboard Fume Hood

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now