• Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
  • Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
  • Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
  • Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
  • Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
  • Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood

Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood

Material: Painted Steel
Type: Bypass Type
Function: Exhaust, Velocity Control, for Chemical Experiments
Feature: Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type: Standard
Color: Optional
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PWNEW-02
Customized
Customized
Condition
New
Other Type
Walk-in Fume Hood
Worktop
Phenolic Resin, Epoxy Resin, Ceramic etc
Other Material
PP, FRP, Stainless Steel etc
Transport Package
Bubble Film+Hard Cotton+Wooden Package
Specification
1200/1500/1800*850*2350mm
Origin
China
HS Code
940320000
Production Capacity
1000 Sets / Year

Product Description

Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
 

A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to:

*Protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes)
*Protect the product or experiment (biosafety cabinets, glove boxes)
*Protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream)


Worktop: Phenolic Resin or Other (Epoxy Resin, Ceramic etc)
Surfaces made of cost effective High Pressure Phenolic Resin composite are resistant to chemical stain and corrosion.  Non-porous and non-conductive, it's strong durable qualities enable it to withstand high impact and shock.  It is easily cleaned with soap and warm water.

Worktop: Epoxy Resin
Because of the natural resistance to corrosion, the industry has found it superior to any other top material for laboratory work.  It is resistant to most organic and inorganic chemicals and is non-toxic.  In addition, it is resistant to mechanical and thermal shock.

 

Constant air volume principle
Conventional hood: This term is used to describe a constant air volume (CAV) hood, an older, traditinally less elaborate hood design used for general protection of the laboratory worker. Because the amount elaborate hood design used for general protection of the laboratory worker. Because the amount of exhausted air is constant, the face velocity of a CAV hood is inversely proportional to the sash height. That is, the lower the sash, the higher the face velocity. CAV hoods can be installed with or without a bypass provision which is an additional opening for air supply into the hood.

Variable air volume vs. constant air volume?
• Constant volume is good for small applications, for dedicated exhaust, or for two to four units sharing an exhaust.
• Most hoods have "setup" time and "run" time, or are only used on a limited basis. While slightly more expensive to buy, that makes a two-speed exhaust more cost effective in use. Typically, low speed is 50% of high speed. Set the blower on high for setup, low for runtime, or for limited-use purposes.
• Hoods should be in close proximity to one another to save money on installing and maintaining the exhaust system.
• You can also plan for future hoods to be added to the system. But make sure future expansion is identified in the building plan, so that the whole building exhaust and supply can accommodate future needs. For example, you can buy a blower for a 4-hood system when you're only planning to install two hoods at first. Then just block off your "future" duct until you buy the additional hoods.


 

Type  Benchtop fume hoods
Exhaust system CAV exhaust system (Constant air volume) or VAV exhaust system
Exhaust fan Inclined flow fan 
Exhaust air rate 1500-3500m3/h
Ventilation ducts PVC material, FPR, PP or other
Power (Single-phase) 220V/50HZ or (Three-phase) 380V/50HZ
Air valve Manual or electric
Average wind speed 0.3-0.6m/s adjustalbe
Noise level < 60dB(A)
Tops Phenolic resin (Other: Epoxy resin, Ceramic etc)
Inner Liner HPL physiochemical board, Phenolic resin, Ceramic

Cabinet

1.0mm thick cold-rolled steel with 75μm epoxy resin powder coating (or phenolic resin plate)

Size

W1200/1500/1800*2100*D960*H2400/2600/2800 mm

Visual windows

Transparent tempered glass, explosion-proof (manual)

Opening height 0-500 mm (Intelligent automatic lifting)

Control panel

Touch, intelligent control panel 

Gross weight  280-400 kg
Motor power 0.5-1.1KW
Luminance >300LX
Lab accessories Pegboard, sink, faucet, gas fitting, sockets, lab stools etc



Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood

Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood
Cav Vav Intelligent Ventilation System Steel PP Lab Fume Hood

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now